OpenTX Reference Guide 12 – telemetry (Set Up)

These parameters set up how telemetry values are displayed on the Telemetry Display screens.

The telemetry parameters are described in the table below.

 

FIELD

PARAMETER

DESCRIPTION

Telemetry Type

FrSky S.PORT

FrSky D

Incomplete

incomplete

This field is not displayed when using an X8R receiver.

A1 Channel

  Range

  Offset

  Low Alarm

  Critical Alarm

0.00

0.0 to 816.00, unit

-Range to +Range

-Range to +Range

-Range to +Range

Receiver analog input value, scaled by Range & Offset.

Units can be v, A, m/s, -, kmh, m, o, %, mA,

The offset has a value limited to the value of +/-‘Range”.

The Low Alarm has a value limited to the value of +/-‘Range”.

The Critical Alarm has a value limited to the value of +/-‘Range”.

A2 Channel

  Range

  Offset

  Low Alarm

  Critical Alarm

Same as A1 above.

Same as A1 above.

A3 Channel

  Range

  Offset

  Low Alarm

  Critical Alarm

Same as A1 above.

Same as A1 above.

A4 Channel

  Range

  Offset

  Low Alarm

  Critical Alarm

Same as A1 above.

Same as A1 above.

RSSI

  Low Alarm

  Critical Alarm

 

15 to 75

12 to 72

Received signal strength indication.

Default = 45,

Default = 42.

User Data

  Blades

  Voltage Source

  Current Source

  FAS Offset

  Persistent mAh

 

1 to 105

 

 

-12.0 to +12.0

 

Default = 2.

A1 to A4, FAS, Cells.

---, A1 to A4, FAS.

Default 0.0   0.0A

When checked, mAh value is retained during power off.

Variometer

  Source

  Limit

 

 

-17 to –3

-2.1 to 0.5

-0.5 to 2.0

3 to 17

 

VSpd, A1, A2, dTE.

Default –10, -5, 0.5 10

Top Bar

  Altitude

 

 

incomplete

Screen 1

---      ---      ---

---      ---      ---

---      ---      ---

---      ---      ---

 

 

---

Nums / Bars

Set here which telemetry values to be displayed on telemetry screen 1.

No value.

Nums mode displays up to 12 numbers.

Bars mode displays up to 4 horizontal bar graphs.

Displayed data can be chosen from the following list.

Batt, Time, Tmr1, Tmr2, RSSI, A1, Alt, Rpm, Fuel, T1, T2, Spd, Dist, Galt, Cell, Cells, Vfas, Curr, Cnsp, Powr, AccX, AccY, AccZ, Hdg, VSpd, Aspd, A1-, A2-, A3-, A4-, Alt-, Alt+, Rpm+, T1+, T2+, Spd+, Dst+, Aspd+, Cell-, Cels-, Vfas-, Curr+, Powr+,

Screen 2

---      ---      ---

---      ---      ---

---      ---      ---

As above for screen 1

As above for screen 1

Screen 3

---      ---      ---

---      ---      ---

---      ---      ---

As above for screen 1

As above for screen 1

 